Pulmonary and Cardiac Ultrasound During Weaning From Mechanical Ventilation
PULCO
2 other identifiers
observational
100
1 country
1
Brief Summary
Prospective observational clinical multicentric study in ICU with ventilated patients requiring chest ultrasound analysis.
Trial Health
Trial Health Score
Automated assessment based on enrollment pace, timeline, and geographic reach
participants targeted
Target at P50-P75 for all trials
Started Feb 2010
Shorter than P25 for all trials
1 active site
Health score is calculated from publicly available data and should be used for screening purposes only.
Trial Relationships
Click on a node to explore related trials.
Study Timeline
Key milestones and dates
Study Start
First participant enrolled
February 1, 2010
CompletedFirst Submitted
Initial submission to the registry
April 1, 2010
CompletedFirst Posted
Study publicly available on registry
April 5, 2010
CompletedPrimary Completion
Last participant's last visit for primary outcome
December 1, 2010
CompletedStudy Completion
Last participant's last visit for all outcomes
December 1, 2010
CompletedJuly 8, 2014
July 1, 2014
10 months
April 1, 2010
July 4, 2014
Conditions
Keywords
Outcome Measures
Primary Outcomes (1)
Compare the change in pulmonary aeration during the test of weaning from mechanical ventilation (before, at the end, and 4-6 h after) between patients requiring re-ventilation before the 48th hour, and those weaned permanently.
Compare the change in pulmonary aeration during the test of weaning from mechanical ventilation (before, at the end, and 4-6 h after) between patients requiring re-ventilation before the 48th hour, and those weaned permanently.
before, at the end, and 4-6 h after
Secondary Outcomes (6)
Studying variations, during weaning from mechanical ventilation, of pressure of left ventricle filling (E / Ea) coupled with those of plasma BNP.
in the 4-6 early hours
Assessing the effects of E / Ea and BNP variations on the success or failure in the 4-6 early hours.
in the 4-6 early hours.
Compare the variations of lung ultrasound score during the test of the weaning from mechanical ventilation between patients failed the spontaneous breathing test (SBT) and those extubated after successful SBT.
in the 4-6 early hours
Comparison of levels epithelial and endothelial markers
at h0, h1, h4, h6
Constitution serum bank for epithelial (sRAGE) markers dosages
at h0, h1, h4, h6
- +1 more secondary outcomes
Study Arms (2)
patients requiring ventilation
patients who weaned permanently
Eligibility Criteria
Prospective observational clinical multicentric study on ICU ventilated patients requiring chest ultrasound analysis during weaning from mechanical ventilation with 48 hours of follow-up. Studying variations of cardiac markers
You may qualify if:
- \- Adult patients ventilated more than 48 h
- Stable respiratory and hemodynamic conditions for SBT
- Consent of patients
- Arterial line
You may not qualify if:
- Laryngeal dyspnea
- Tracheostomy
- Arythmya
- No echogenicity
- Paraplegia \>T8
Contact the study team to confirm eligibility.
Sponsors & Collaborators
Study Sites (1)
CHU Clermont-Ferrand
Clermont-Ferrand, 63003, France
Related Publications (1)
Jabaudon M, Perbet S, Pereira B, Soummer A, Roszyk L, Guerin R, Futier E, Lu Q, Bazin JE, Sapin V, Rouby JJ, Constantin JM. Plasma levels of sRAGE, loss of aeration and weaning failure in ICU patients: a prospective observational multicenter study. PLoS One. 2013 May 27;8(5):e64083. doi: 10.1371/journal.pone.0064083. Print 2013.
PMID: 23724022DERIVED
Study Officials
- PRINCIPAL INVESTIGATOR
Sébastien PERBET
University Hospital, Clermont-Ferrand
Study Design
- Study Type
- observational
- Time Perspective
- CROSS SECTIONAL
- Sponsor Type
- OTHER
- Responsible Party
- SPONSOR
Study Record Dates
First Submitted
April 1, 2010
First Posted
April 5, 2010
Study Start
February 1, 2010
Primary Completion
December 1, 2010
Study Completion
December 1, 2010
Last Updated
July 8, 2014