NCT00930878

Brief Summary

The purpose of this study is to collect real-life data of the Promus™ stent, the Cypher™ stent and the Endeavor™ stent in routine clinical practice, and compare outcomes.

Trial Health

87
On Track

Trial Health Score

Automated assessment based on enrollment pace, timeline, and geographic reach

Enrollment
1,934

participants targeted

Target at P75+ for all trials

Timeline
Completed

Started Feb 2008

Typical duration for all trials

Geographic Reach
1 country

1 active site

Status
completed

Health score is calculated from publicly available data and should be used for screening purposes only.

Trial Relationships

Click on a node to explore related trials.

Study Timeline

Key milestones and dates

Study Start

First participant enrolled

February 1, 2008

Completed
2 months until next milestone

First Submitted

Initial submission to the registry

March 26, 2008

Completed
1.3 years until next milestone

First Posted

Study publicly available on registry

July 2, 2009

Completed
8 months until next milestone

Primary Completion

Last participant's last visit for primary outcome

March 1, 2010

Completed
Same day until next milestone

Study Completion

Last participant's last visit for all outcomes

March 1, 2010

Completed
Last Updated

February 3, 2017

Status Verified

February 1, 2017

Enrollment Period

2.1 years

First QC Date

March 26, 2008

Last Update Submit

February 2, 2017

Conditions

Keywords

registrydrug eluting coronary stent systemobservationalprospectiveopen-label

Outcome Measures

Primary Outcomes (1)

  • Rate of composite patient-oriented hierarchical Major Cardiac Events and its individual components (cardiac death, any Myocardial Infarction (MI) and Target Vessel Revascularisation (TVR) as classified by an External Medical Monitoring Committee.

    at 12-month post index procedure

Secondary Outcomes (1)

  • Technical Success, Stent deliverability, Rate of composite stent-oriented hierarchical Major Cardiac Events and its individual components, TVR rates, TLR rates, Rate of all death, Rate of stent thrombosis

    at 6 and/or 12 months post index procedure

Study Arms (3)

Promus

Patients intended to be treated with a Promus™ stent system

Device: Cardiac Stenting

Endeavor

Patients intended to be treated with an Endeavor™ stent system (excluded the Endeavor™ Resolute™ stent)

Device: Cardiac Stenting

Cypher

Patients intended to be treated with a Cypher™ stent system

Device: Cardiac Stenting

Interventions

Drug Eluting stent

CypherEndeavorPromus

Eligibility Criteria

Age18 Years+
Sexall
Healthy VolunteersNo
Age GroupsAdult (18-64), Older Adult (65+)
Sampling MethodProbability Sample
Study Population

All patients eligible and planned for percutaneous coronary intervention (PCI) with any of the three stents and willing to give consent to allow for collection of their clinical data. Patients also need to express willingness to comply with all standard of care follow-up evaluations and medical therapies.

You may qualify if:

  • Per PROMUS or CYPHER or Endeavor DFU/IFU
  • PROMUS Indications:
  • PROMUS™ Everolimus Eluting Coronary Stent System is indicated for improving coronary luminal diameter in patients with symptomatic ischemic heart disease due to discrete de novo native coronary artery lesions (length 28 mm) with a reference vessel diameter of 2.5 mm - 4.0 mm.
  • CYPHER Indications:
  • CYPHER SELECT Sirolimus-eluting Coronary Stent is indicated for improving coronary luminal diameter in patients with symptomatic ischemic disease due to discrete de novo and in-stent restenotic lesions (length 30 mm) in native coronary arteries with a reference vessel diameter of 2.25 mm to 5.00 mm.
  • Endeavor Indications:
  • Endeavor Stent is indicated for improving coronary luminal diameter and reducing restenosis in patients with symptomatic ischemic heart disease in de novo coronary artery lesions in native coronary arteries with a reference vessel diameter of 2.25 mm to 4.0 mm and a lesion length of \< 27 mm.

You may not qualify if:

  • PROMUS Contraindications:
  • Patients in whom anti-platelet and / or anti-coagulant therapy is contraindicated.
  • Patients judged to have a lesion that prevents complete inflation of an angioplasty balloon.
  • Patients with a known hypersensitivity or contraindication to everolimus, cobalt, chromium, nickel, tungsten, acrylic and fluoro - polymers may have an allergic reaction to this implant; therefore, the implant is not recommended for such patients.
  • CYPHER Contraindications:
  • Patients in whom antiplatelet and/or anticoagulation therapy is contraindicated.
  • Patients judged to have a lesion that prevents complete inflation of an angioplasty balloon.
  • Transplant patients.
  • Endeavor Contraindications:
  • Patients with hypersensitivity or allergies to aspirin, heparin, clopidogrel, ticlopidine, drugs such as ABT-578, rapamycin, tacrolimus, sirolimus or similar drugs or any other analogue or derivative, cobalt, chromium, nickel, molybdenum, or contrast media.
  • Patients in whom antiplatelet and/or anticoagulation therapy is contraindicated.
  • Patients who are judged to have a lesion that prevents complete inflation of an angioplasty balloon.

Contact the study team to confirm eligibility.

Sponsors & Collaborators

Study Sites (1)

Kerckhoff-Klinik GmbH

Bad Nauheim, Hesse, 61231, Germany

Location

Study Officials

  • Christian Hamm, MD

    Kerckhoff-Klinik GmbH

    PRINCIPAL INVESTIGATOR

Study Design

Study Type
observational
Observational Model
COHORT
Time Perspective
PROSPECTIVE
Sponsor Type
INDUSTRY
Responsible Party
SPONSOR

Study Record Dates

First Submitted

March 26, 2008

First Posted

July 2, 2009

Study Start

February 1, 2008

Primary Completion

March 1, 2010

Study Completion

March 1, 2010

Last Updated

February 3, 2017

Record last verified: 2017-02

Data Sharing

IPD Sharing
Will not share

Locations